====== Scripts for HP servers in CLI ====== ===== Start CLI ===== hpacucli Find Controller ctrl all show Smart Array P410i in Slot 0 (Embedded) Bus Interface: PCI Select card and view logical drives ctrl slot="0" ld all show Smart Array P410i in Slot 0 (Embedded) array A logicaldrive 1 (136.7 GB, RAID 1, OK) array B logicaldrive 2 (558.7 GB, RAID 1+0, OK) array C logicaldrive 3 (279.4 GB, RAID 1, OK) Check Physical Drives ctrl slot="0" pd all show Smart Array P410i in Slot 0 (Embedded) array A physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 146 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 146 GB, OK) array B physicaldrive 2I:1:5 (port 2I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 2I:1:6 (port 2I:box 1:bay 6, SAS, 300 GB, OK) physicaldrive 2I:1:7 (port 2I:box 1:bay 7, SAS, 300 GB, OK) physicaldrive 2I:1:8 (port 2I:box 1:bay 8, SAS, 300 GB, OK) array C physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK)